If any of the steps in the Press subset are listed below, check the information in the description:
STEP: | DESCRIPTION: |
0.1 | Check that there is the following inputs: "Mould Closed" and "Enable Operation With Handling Device/Robot"Check that there is not the following inputs: "Mould Open" and "Mould Intermediate Position". |
0.2 | Check that there is not the following inputs: "Mould Open" and "Mould Intermediate Position" and "Mould Closed". |
0.4 | Check that there is the following inputs: "Enable Operation With Handling Device/Robot" and (if parameter #101 is equal to 0, check that there is the "Mould Open" input, if parameter #101 is equal to 1, check that it has the "Mould Intermediate Position" input).Check that there is not the following input: "Mould Open". |
0.8 | Check that the actual position of the robot axis is lower than the approach position. |